← Back to CVE List

CVE-2017-6015

Published: 2018-05-11T13:29Z
Last Modified: 2024-11-21T03:28Z
Source: MITRE CVE List
License: MITRE-CVE-TOS
Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later. > MITRE Terms of Use apply – see LICENSE‑MITRE.txt