← Back to CVE List

CVE-2018-0026

Published: 2018-07-11T18:29Z
Last Modified: 2024-11-21T03:37Z
Source: MITRE CVE List
License: MITRE-CVE-TOS
After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME-<interface_name> This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3. > MITRE Terms of Use apply – see LICENSE‑MITRE.txt